BONA FIDE MECHANICAL HVAC
WE LOVE EXCELLENCE WITHOUT COMPROMISE CONTROLS
THERE MODULATING BY-PASS DAMPER IS THE MOST FUNCTIONAL
AUTOMATIC DAMPER WE'VE WORKED WITH.
WE DON'T USE DUMP ZONES, SO THESE ROUND DAMPERS ARE A MUST
ESPECIALLY WHEN CONVERTING TO MORE THAN 2 ZONES, IT ALLOWS FOR
STEADY STATIC PRESSURE NO MATTER HOW MANY THERMOSTATS ARE
CALLING.










Fresh Air System

This Fresh Air System utilizes outside air to automatically provide comfort without running the air conditioning when in the cooling
mode. The system consists of an EC (Enthalpy Control), a fresh air control panel and outside air dampers. The EC is a control that
will sense the temperature and humidity in the air around it. This is adjustable for the desired set point. With the EC in operation
this will allow for a very economical way to cool your home or building with fresh air. The EC is wired to an HK2000 which will open
the outside air damper and turn on the fan to circulate the air to where it is needed. This will only happen when there is a thermostat
calling for cooling and the EC senses that the outside air can do the job before using the air conditioning. Once the outside air is not
acceptable, the fresh air system will shut down and turn on the air conditioning.
How the Ultra-Zone System Works

The purpose of the Ultra-Zone system is to provide total comfort in the home and office.  Motorized dampers
are "opened" or "closed" by thermostats based on the temperature set point of the homeowner.  The damper
system will control the airflow through the ductwork and deliver ONLY the desired air to the desired location.  
Each thermostat has the ability to turn on and shut off the heating and cooling.  The Ultra-Zone system can
accommodate over 30 zones.  This means that over 30 thermostats can be installed in a home or building to
control the temperature in each zone.

There are very few Ultra-Zone components that are needed to make the zoning system function.  The control
panel is the "brain" of the system.  The zone thermostats allow independent temperature control and the zone
dampers control the airflow to the zone thermostats.  A transformer is needed to power the system and
occasionally a by-pass damper may be required.

The basic components of an Ultra-Zone system are:

1) A Control Panel 4) Dedicated Transformer
2) Zone Thermostats 5) By-pass Damper (If necessary)
3) Zone Dampers  

Along with some thermostat wire, these are the only components that are needed to install an Ultra-Zone
system.  The above diagram shows a typical installation with all of the components needed for a zoning
system.